0 |
0 |
EVT_PZ_ChanEnd |
SIS/ESR PZ only: mark end of channel |
N |
1 |
1 |
EVT_START_RF |
Power to RF cavities |
Y |
2 |
2 |
EVT_START_IQ |
Begin of beam production |
Y |
3 |
3 |
EVT_IQ_HEATING |
Begin of ion source arc, ECR RF |
Y |
4 |
4 |
EVT_PREP_BEAM_ON |
Switch on chopper, read act. values |
Y |
5 |
5 |
EVT_IQ_GAS_ON |
Start of heading gas (ion source) |
Y |
6 |
6 |
EVT_BEAM_ON |
Valid beam |
Y |
8 |
8 |
EVT_BEAM_OFF |
End of beam production |
Y |
10 |
A |
EVT_STOP_IQ |
Switch IQ off |
Y |
12 |
C |
EVT_STOP_RF |
Switch RF off |
Y |
16 |
10 |
EVT_PREP_NEXT_ACC |
Prepare next acc., write set values |
Y |
17 |
11 |
EVT_AUX_PRP_NXT_ACC |
Set values in magnet prep. cycles |
N |
18 |
12 |
EVT_RF_PREP_NXT_ACC |
Begin of RF extra cycle |
Y |
19 |
13 |
EVT_PREP_UNI_DIAG |
Prepare diagnostic devices, Unilac |
N |
20 |
14 |
EVT_PREP_AUX |
Trigger BIF beam diagnostics |
Y |
21 |
15 |
EVT_UNLOCK_ALVAREZ |
Unlock A4 for next pulse |
N |
22 |
16 |
EVT_PREP_EXP |
Pretrigger for Experiments |
Y |
24 |
18 |
EVT_RF_AUX_TRIG |
Trigger ADC in RF extra cycles |
Y |
25 |
19 |
EVT_MAGN_DOWN |
Set magnets to zero current |
Y |
26 |
1A |
EVT_SD_AUX_START |
Beam diagnostics aux start trigger |
Y |
27 |
1B |
EVT_SD_AUX_STOP |
Beam diagnostics aux stop trigger |
Y |
28 |
1C |
EVT_PRETRIG_BEAM |
Magnets on flattop, PG trigger |
Y |
29 |
1D |
EVT_UNI_END_CYCLE |
End of a UNILAC cycle |
N |
30 |
1E |
EVT_READY_TO_SIS |
10 ms before beam transfer |
N |
31 |
1F |
EVT_SRC_DST_ID |
Source/Destination of beam |
N |
32 |
20 |
EVT_START_CYCLE |
First Event in a cycle |
N |
33 |
21 |
EVT_START_BFELD |
Start of B-Field |
N |
34 |
22 |
EVT_PEAK_UP |
Peaking trip up |
N |
35 |
23 |
EVT_INJECT |
B-field reached injection level |
Y |
36 |
24 |
EVT_UNI_TRANS |
Demand UNILAC beam |
N |
37 |
25 |
EVT_UNI_ACKN |
Acknowledge from Unilac |
N |
38 |
26 |
EVT_UNI_READY |
Unilac ready, transfer in preparation |
N |
39 |
27 |
EVT_MB_LOAD |
Start Bumper magnet ramp up |
Y |
40 |
28 |
EVT_MB_TRIGGER |
Start active Bumper Ramp (down) |
Y |
41 |
29 |
EVT_INJECT_END |
Start of injection from unilac |
Y |
42 |
2A |
EVT_TIMEOUT_1 |
Trigger timeout channel 1 |
N |
43 |
2B |
EVT_RAMP_START |
Start of acc/deacc ramp in magnets |
Y |
44 |
2C |
EVT_PREP_INJ |
Prepare devices for next Injection |
Y |
45 |
2D |
EVT_FLATTOP |
Magnets reached Flattop |
Y |
46 |
2E |
EVT_EXTR_START_SLOW |
Start of extraction |
Y |
47 |
2F |
EVT_MK_LOAD_1 |
Load Kicker for HF-triggered puls |
Y |
48 |
30 |
EVT_MK_LOAD_2 |
Load Kicker for Timinggenerator-triggered puls |
Y |
49 |
31 |
EVT_KICK_START_1 |
Start Kicker for HF-triggered extraction |
Y |
50 |
32 |
EVT_TIMEOUT_2 |
Trigger timeout channel 2 |
N |
51 |
33 |
EVT_EXTR_END |
End of extraction |
Y |
52 |
34 |
EVT_FLATTOP_END |
End of Flattop (Magnets) reached |
Y |
53 |
35 |
EVT_PREP_EXTR |
Prepare devices for next Extraction |
Y |
54 |
36 |
EVT_PEAK_DOWN |
Peaking strip down |
N |
55 |
37 |
EVT_END_CYCLE |
End of a cycle |
N |
56 |
38 |
EVT_SYNCH |
Trigger all function generators |
Y |
57 |
39 |
EVT_EXTR_BUMP |
Start of closed orbit distortion |
Y |
58 |
3A |
EVT_SIS_ACK_TO_ESR |
SIS acknowledge to ESR |
N |
59 |
3B |
EVT_SIS_READY_1 |
SIS ready for extraction to ESR |
N |
60 |
3C |
EVT_SIS_READY_2 |
SIS ready for extraction to ESR |
N |
61 |
3D |
EVT_TRANS_START_1 |
Begin of transmission to ESR |
N |
62 |
3E |
EVT_TRANS_START_2 |
Begin of transmission to ESR |
N |
63 |
3F |
EVT_PHASE_SYNCH_GATE_1 |
Begin of first phase synchronisation between ESR- and SIS-HF |
N |
64 |
40 |
EVT_TIMEOUT_3 |
Trigger timeout channel 3 |
N |
65 |
41 |
EVT_PHASE_SYNCH_GATE_2 |
Begin of second phase synchronisation between ESR- and SIS-HF |
N |
66 |
42 |
EVT_TIMEOUT_4 |
Trigger timeout channel 4 |
N |
67 |
43 |
EVT_TIMEOUT_5 |
Trigger timeout channel 5 |
N |
68 |
44 |
EVT_TIMEOUT_6 |
Trigger timeout channel 6 |
N |
69 |
45 |
EVT_KICK_START_2 |
Start Kicker for TG-triggered extraction |
Y |
70 |
46 |
EVT_UNI_PREP |
Demand setting of TK (200 ms before beam) |
N |
71 |
47 |
EVT_INJ_BUMP |
Closed orbit destortion for reinjection |
Y |
72 |
48 |
EVT_RE_INJ_START |
SIS is ready for reinjection |
N |
73 |
49 |
EVT_RE_INJ_END |
End of reinjection |
N |
74 |
4A |
EVT_PREP_RE_INJ |
Prepare devices for Reinjection |
N |
75 |
4B |
EVT_PREP_KICK_1 |
Prepare kicker: load capacitor 1 |
Y |
76 |
4C |
EVT_PREP_KICK_2 |
Prepare kicker: load capacitor 2 |
Y |
77 |
4D |
EVT_MK_LOAD_RE_INJ |
Load Kicker for Reinjection |
N |
78 |
4E |
EVT_EXTR_STOP_SLOW |
End of slow extraction |
Y |
79 |
4F |
EVT_ASYNC_TRANS |
Transfer to ESR without HF synchron. |
Y |
80 |
50 |
EVT_EMA_START |
Start EMA meassurement gate |
Y |
81 |
51 |
EVT_HF_BM_START |
Vorbereitung Strahlgym. |
Y |
82 |
52 |
EVT_HF_BM_AMPH2 |
Start Ampl., Ph. Kav. 2 Strahlgym. |
Y |
83 |
53 |
EVT_HF_BM_FREQ2 |
Start Freq. Kav. 2 Strahlgym. |
Y |
84 |
54 |
EVT_HF_BM_AMPH12 |
Start Ampl., Ph. Kav. 1+2 Strahlgym. |
Y |
85 |
55 |
EVT_HF_BM_FREQ1 |
Start Freq. Kav. 1 Strahlgym. |
Y |
86 |
56 |
EVT_HF_BM_AMPH1 |
Start Ampl., Ph. Kav. 1 Strahlgym. |
Y |
87 |
57 |
EVT_TG_CLEAR |
Clear Timinggenerator |
Y |
88 |
58 |
EVT_MQ_START1 |
Load Q-Kicker (1st shot) |
Y |
89 |
59 |
EVT_MQ_START2 |
Load Q-Kicker (2nd shot) |
Y |
90 |
5A |
EVT_MQ_MESS |
Trigger for Q-Wert measurement |
Y |
91 |
5B |
EVT_INT_FLAT |
Start of internal Flattop |
Y |
92 |
5C |
EVT_DT_MESS |
Trigger for DTML measurement |
Y |
93 |
5D |
EVT_DX_MESS |
Trigger for DX measurement |
Y |
94 |
5E |
EVT_TG_SWITCH |
Umschalten der TG synchronisation |
Y |
95 |
5F |
EVT_START_LECROY |
Start measurement with LeCroy |
Y |
96 |
60 |
EVT_GAP_POS_MESS |
Messevent zwischen den Zyklen |
N |
97 |
61 |
EVT_GAP_TRA_MESS |
Messevent zwischen den Zyklen |
N |
98 |
62 |
EVT_GAP_SCR_MESS |
Messevent zwischen den Zyklen |
N |
99 |
63 |
EVT_GAP_DTS_MESS |
Messevent für schnelle Trafos |
N |
100 |
64 |
EVT_SIS_TRANS1_ESR |
First transmission complete to ESR |
N |
101 |
65 |
EVT_SIS_TRANS2_ESR |
Second transmission complete to ESR |
N |
102 |
66 |
EVT_PREP_DIAGNOSE |
... |
Y |
103 |
67 |
EVT_PREP_DG |
Vorbereitung Gitterhardware |
Y |
104 |
68 |
EVT_DG_TRIGGER |
Trigger Messung Gitterhardware |
Y |
105 |
69 |
EVT_KICK_READY |
Ext. Synchronisat. für Kicker |
Y |
106 |
6A |
EVT_KICK_GATE |
Start externe Synchr. für Kicker |
Y |
107 |
6B |
EVT_PREP_DTI |
Entklemmung TK trafos SIS timing |
Y |
108 |
6C |
EVT_INJ_READY |
Einzelne Unilac-Injektion erfolgt |
Y |
109 |
6D |
EVT_MHB |
Multi-Harmonischer-Betrieb von GS00BE_S (SIS18) |
Y |
128 |
80 |
EVT_ESR_READY_1 |
ESR ready for beam transfer |
N |
129 |
81 |
EVT_ESR_READY_2 |
ESR ready for beam transfer |
N |
130 |
82 |
EVT_ESR_REQ_TO_SIS |
ESR beam request to SIS |
N |
131 |
83 |
EVT_EIN1 |
ESR ????? 1 |
N |
132 |
84 |
EVT_EIN2 |
ESR ????? 2 |
N |
133 |
85 |
EVT_MAN1 |
ESR manipulation 1 |
N |
134 |
86 |
EVT_MAN2 |
ESR manipulation 2 |
N |
135 |
87 |
EVT_PHASE_SYNCH_1 |
Phase is 1st time synchronized between ESR- and SIS-HF |
N |
136 |
88 |
EVT_PHASE_SYNCH_2 |
Phase is 2nd time synchronized between ESR- and SIS-HF |
N |
137 |
89 |
EVT_NO_BEAM |
There is no beam in ESR (for diagnostics) |
Y |
138 |
8A |
EVT_DT_STOP |
Stop of DTML measurement |
Y |
139 |
8B |
EVT_DT_READ |
Read data for DTML measurement |
Y |
140 |
8C |
EVT_DX_STOP |
Stop of DX measurement |
Y |
141 |
8D |
EVT_DX_READ |
Read data for DX measurement |
Y |
142 |
8E |
EVT_LEXT |
ESR start with ????????????? |
N |
143 |
8F |
EVT_PSTACK |
ESR start with ????????????? |
N |
144 |
90 |
EVT_STACK |
ESR start with ????????????? |
N |
145 |
91 |
EVT_ESR_TRANS_SIS |
Transmission complete to SIS |
N |
146 |
92 |
EVT_ECE_HV_VAR |
Stepwise variation of ECE voltage |
Y |
147 |
93 |
EVT_ECE_HV_ON |
Write set value for pulsed ECE HV |
Y |
148 |
94 |
EVT_ECE_HV_MESS |
Read actual value of pulsed ECE HV |
Y |
149 |
95 |
EVT_BUNCH_ROTATE |
Start with bunch rotation |
Y |
150 |
96 |
EVT_ESR_REQ_REINJ |
ESR request SIS reinjection |
N |
151 |
97 |
EVT_RESET |
Start of 11th Ramp in magnets |
Y |
152 |
98 |
EVT_AUS1 |
Start of 11th Ramp in magnets |
N |
153 |
99 |
EVT_AUS2 |
Start of 11th Ramp in magnets |
N |
154 |
9A |
EVT_RAMP_11 |
Start of 11th Ramp in magnets |
N |
155 |
9B |
EVT_RAMP_12 |
Start of 12th Ramp in magnets |
N |
156 |
9C |
EVT_RAMP_13 |
Start of 13th Ramp in magnets |
N |
157 |
9D |
EVT_RAMP_14 |
Start of 14th Ramp in magnets |
N |
158 |
9E |
EVT_RAMP_15 |
Start of 15th Ramp in magnets |
N |
159 |
9F |
EVT_RAMP_16 |
Start of 16th Ramp in magnets |
N |
160 |
A0 |
EVT_EBEAM_ON |
Electron beam on |
Y |
161 |
A1 |
EVT_EBEAM_OFF |
Electron beam off |
Y |
162 |
A2 |
EVT_UDET_IN |
Move detector (charge changed) in |
Y |
163 |
A3 |
EVT_UDET_OUT |
Move detector out |
Y |
180 |
B4 |
EVT_TIMING_LOCAL |
Take local timing |
N |
181 |
B5 |
EVT_TIMING_EXTERN |
Switch to extern timing |
N |
199 |
C7 |
EVT_INTERNAL_FILL |
PZ: Fill long event delays (>10s) |
N |
200 |
C8 |
EVT_DATA_START |
First data transfer event |
N |
201 |
C9 |
EVT_DATA_0 |
Data transfer event |
N |
202 |
CA |
EVT_DATA_1 |
Data transfer event |
N |
203 |
CB |
EVT_DATA_2 |
Data transfer event |
N |
204 |
CC |
EVT_DATA_3 |
Data transfer event |
N |
205 |
CD |
EVT_DATA_4 |
Data transfer event |
N |
206 |
CE |
EVT_DATA_5 |
Data transfer event |
N |
207 |
CF |
EVT_DATA_6 |
Data transfer event |
N |
208 |
D0 |
EVT_DATA_7 |
Data transfer event |
N |
209 |
D1 |
EVT_TIME_1 |
Time stamp, most sign. bits |
N |
210 |
D2 |
EVT_TIME_2 |
Time stamp, medium sign. bits |
N |
211 |
D3 |
EVT_TIME_3 |
Time stamp, least sign. bits |
N |
224 |
E0 |
EVT_UTC_1 |
Time stamp UTC bits 32..39 |
N |
225 |
E1 |
EVT_UTC_2 |
Time stamp UTC bits 24..31 |
N |
226 |
E2 |
EVT_UTC_3 |
Time stamp UTC bits 16..23 |
N |
227 |
E3 |
EVT_UTC_4 |
Time stamp UTC bits 8..15 |
N |
228 |
E4 |
EVT_UTC_5 |
Time stamp UTC bits 0.. 7 |
N |
245 |
F5 |
EVT_END_CMD_EXEC |
End of command evaluation within gap |
N |
246 |
F6 |
EVT_BEGIN_CMD_EXEC |
Start of command evaluation within gap |
N |
247 |
F7 |
EVT_GAP_INFO |
PZ information about next cycle |
N |
248 |
F8 |
EVT_COLL_DET |
PZ detected collision of 2 asynch. events |
N |
249 |
F9 |
EVT_TIMING_DIAG |
For diagnostics in timing system |
N |
250 |
FA |
EVT_SUP_CYCLE_START |
Supercycle starts |
N |
251 |
FB |
EVT_GET_EC_TIME |
Synchronous reading of time of all ECs |
N |
252 |
FC |
EVT_SET_EC_TIME |
Synchronous setting of time in all ECs |
N |
253 |
FD |
EVT_RESERVED |
In older systems : change vrtacc event |
N |
254 |
FE |
EVT_EMERGENCY |
Emergency event |
N |
255 |
FF |
EVT_COMMAND |
Command event |
Y |
256 |
100 |
CMD_BP_START |
Start of Beam Process |
Y |
257 |
101 |
CMD_SEQ_START |
Sequence start. Implicitly, a CMD_SEQ_START is also a CMD_BP_START |
Y |
258 |
102 |
CMD_GAP_START |
Start of gap window. Within this window, background tasks can be performed safely. |
Y |
259 |
103 |
CMD_GAP_END |
End of gap window. Within this window, background tasks can be performed safely. |
Y |
270 |
10E |
CMD_SOURCE_BEAM_ON |
Source Beam On |
Y |
271 |
10F |
CMD_SOURCE_BEAM_OFF |
Source Beam Off |
Y |
272 |
110 |
CMD_SOURCE_HV_PREP |
HV Preparation for the Source |
Y |
273 |
111 |
CMD_SOURCE_START |
Start beam production in source |
Y |
274 |
112 |
CMD_SOURCE_STOP |
Stop beam production in source and switch source to standby |
Y |
280 |
118 |
CMD_BI_TRIGGER |
Beam Diagnostics: Trigger |
Y |
281 |
119 |
CMD_BI_MEAS1 |
Beam Diagnostics: Measure Event 1 |
Y |
282 |
11A |
CMD_BI_MEAS2 |
Beam Diagnostics: Measure Event 2 |
Y |
283 |
11B |
CMD_BEAM_INJECTION |
Injection into a ring machine; played shortly prior to each injection within a sequence |
Y |
284 |
11C |
CMD_BEAM_EXTRACTION |
Extraction from a ring machine; played shortly prior to each extraction within a sequence |
Y |
285 |
11D |
CMD_START_ENERGY_RAMP |
Start acceleration or deceleration; only for beam-in processes; intended for diagnostic purposes |
Y |
286 |
11E |
CMD_CUSTOM_DIAG_1 |
Intended for diagnostic purposes |
Y |
287 |
11F |
CMD_CUSTOM_DIAG_2 |
Intended for diagnostic purposes |
Y |
288 |
120 |
CMD_CUSTOM_DIAG_3 |
Intended for diagnostic purposes |
Y |
290 |
122 |
CMD_RF_PREP |
RF: Prepare device for pulse generation |
Y |
291 |
123 |
CMD_RF_PREP_PAUSE |
RF: Prepare device for pulse generation (paused operation and beam-out) |
Y |
292 |
124 |
CMD_RF_STOP_PAUSE |
RF: Stop generation of pulse (paused operation and beam-out) |
Y |
312 |
138 |
CMD_SYNCH |
Trigger all function generators |
Y |
313 |
139 |
CMD_RF_SWITCH_01 |
Change RF system operation mode according to predefined settings |
Y |
314 |
13A |
CMD_RF_SWITCH_02 |
Change RF system operation mode according to predefined settings |
Y |
315 |
13B |
CMD_RF_SWITCH_03 |
Change RF system operation mode according to predefined settings |
Y |
316 |
13C |
CMD_RF_SWITCH_04 |
Change RF system operation mode according to predefined settings |
Y |
317 |
13D |
CMD_RF_SWITCH_05 |
Change RF system operation mode according to predefined settings |
Y |
318 |
13E |
CMD_RF_SWITCH_06 |
Change RF system operation mode according to predefined settings |
Y |
319 |
13F |
CMD_RF_SWITCH_07 |
Change RF system operation mode according to predefined settings |
Y |
320 |
140 |
CMD_RF_SWITCH_08 |
Change RF system operation mode according to predefined settings |
Y |
321 |
141 |
CMD_RF_SWITCH_09 |
Change RF system operation mode according to predefined settings |
Y |
322 |
142 |
CMD_RF_SWITCH_10 |
Change RF system operation mode according to predefined settings |
Y |
323 |
143 |
CMD_RF_SWITCH_11 |
Change RF system operation mode according to predefined settings |
Y |
324 |
144 |
CMD_RF_SWITCH_12 |
Change RF system operation mode according to predefined settings |
Y |
325 |
145 |
CMD_RF_SWITCH_13 |
Change RF system operation mode according to predefined settings |
Y |
326 |
146 |
CMD_RF_SWITCH_14 |
Change RF system operation mode according to predefined settings |
Y |
327 |
147 |
CMD_RF_SWITCH_15 |
Change RF system operation mode according to predefined settings |
Y |
328 |
148 |
CMD_RF_SWITCH_16 |
Change RF system operation mode according to predefined settings |
Y |
329 |
149 |
CMD_RF_SWITCH_17 |
Change RF system operation mode according to predefined settings |
Y |
330 |
14A |
CMD_RF_SWITCH_18 |
Change RF system operation mode according to predefined settings |
Y |
331 |
14B |
CMD_RF_SWITCH_19 |
Change RF system operation mode according to predefined settings |
Y |
332 |
14C |
CMD_RF_SWITCH_20 |
Change RF system operation mode according to predefined settings |
Y |
333 |
14D |
CMD_RF_SWITCH_21 |
Change RF system operation mode according to predefined settings |
Y |
334 |
14E |
CMD_RF_SWITCH_22 |
Change RF system operation mode according to predefined settings |
Y |
335 |
14F |
CMD_RF_SWITCH_23 |
Change RF system operation mode according to predefined settings |
Y |
336 |
150 |
CMD_RF_SWITCH_24 |
Change RF system operation mode according to predefined settings |
Y |
337 |
151 |
CMD_RF_SWITCH_25 |
Change RF system operation mode according to predefined settings |
Y |
338 |
152 |
CMD_RF_SWITCH_26 |
Change RF system operation mode according to predefined settings |
Y |
339 |
153 |
CMD_RF_SWITCH_27 |
Change RF system operation mode according to predefined settings |
Y |
340 |
154 |
CMD_RF_SWITCH_28 |
Change RF system operation mode according to predefined settings |
Y |
341 |
155 |
CMD_RF_SWITCH_29 |
Change RF system operation mode according to predefined settings |
Y |
342 |
156 |
CMD_RF_SWITCH_30 |
Change RF system operation mode according to predefined settings |
Y |
343 |
157 |
CMD_RF_SWITCH_31 |
Change RF system operation mode according to predefined settings |
Y |
344 |
158 |
CMD_RF_SWITCH_32 |
Change RF system operation mode according to predefined settings |
Y |
345 |
159 |
CMD_RF_PHASE_RESET |
Trigger the DDS phase reset for RF devices |
Y |
350 |
15E |
CMD_UNI_TCREQ |
Request UNILAC PZ to reserve the transfer channel |
N |
351 |
15F |
CMD_UNI_TCREL |
Request UNILAC PZ to release the transfer channel |
N |
352 |
160 |
CMD_UNI_BREQ |
Request UNILAC PZ to deliver beam |
N |
353 |
161 |
CMD_UNI_BPREP |
Request UNILAC PZ to prepare beam delivery |
N |
354 |
162 |
CMD_UNI_BREQ_NOWAIT |
Request UNILAC PZ to deliver beam but without 'wait block' in Data Master schedule |
N |
512 |
200 |
CMD_FG_PREP |
Prepare function generator |
Y |
513 |
201 |
CMD_FG_START |
Start function generator |
Y |
518 |
206 |
CMD_BEAM_ON |
General: Begin of beam passage |
Y |
520 |
208 |
CMD_BEAM_OFF |
General: End of beam passage |
Y |
521 |
209 |
CMD_SEPTUM_CHARGE |
Start septum ramp up |
Y |
522 |
20A |
CMD_EBEAM_ON |
Electron beam on |
Y |
523 |
20B |
CMD_EBEAM_OFF |
Electron beam off |
Y |
524 |
20C |
CMD_STOCH_COOLING_ON |
Stochastic cooling on |
Y |
525 |
20D |
CMD_STOCH_COOLING_OFF |
Stochastic cooling off |
Y |
526 |
20E |
CMD_TARGET_ON |
Enable target |
Y |
527 |
20F |
CMD_TARGET_OFF |
Disable target |
Y |
528 |
210 |
CMD_EXP_DAQ_START |
Start experiment data acquisition |
Y |
529 |
211 |
CMD_EXP_DAQ_STOP |
Stop experiment data acquisition |
Y |
530 |
212 |
CMD_EXP_DRIVE_IN |
Move experiment actuators (detectors) to measurement position |
Y |
531 |
213 |
CMD_EXP_DRIVE_OUT |
Move experiment actuators (detectors) to outside position (clear beam aperture) |
Y |
532 |
214 |
CMD_DRIVE_MOVE |
Move timing-controlled actuators to new position |
Y |
539 |
21B |
CMD_CHOPPER_CHARGE |
Start energizing chopper |
Y |
1024 |
400 |
CMD_BUMPER_CHARGE |
Start bumper magnet ramp up |
Y |
1025 |
401 |
CMD_BUMPER_START |
Start bumper ramp down |
Y |
1026 |
402 |
CMD_INJ_KICKER_START |
Start injection kicker |
Y |
1027 |
403 |
CMD_EXTR_KICKER_START |
Start extraction kicker |
Y |
2048 |
800 |
CMD_B2B_PMEXT |
B2B internal: request phase measurement (extraction) |
N |
2049 |
801 |
CMD_B2B_PMINJ |
B2B internal: request phase measurement (injection) |
N |
2050 |
802 |
CMD_B2B_PREXT |
B2B internal: send result of phase measurement (extraction) |
N |
2051 |
803 |
CMD_B2B_PRINJ |
B2B internal: send result of phase measurement (injection) |
N |
2052 |
804 |
CMD_B2B_TRIGGEREXT |
B2B: trigger kicker electronics (extraction) |
Y |
2053 |
805 |
CMD_B2B_TRIGGERINJ |
B2B: trigger kicker electronics (injection) |
Y |
2054 |
806 |
CMD_B2B_DIAGKICKEXT |
B2B: send result of kick diagnostic (extraction) |
Y |
2055 |
807 |
CMD_B2B_DIAGKICKINJ |
B2B: send result of kick diagnostic (injection) |
Y |
2056 |
808 |
CMD_B2B_DIAGEXT |
B2B internal: send result of optional diagnostic (extraction) |
N |
2057 |
809 |
CMD_B2B_DIAGINJ |
B2B internal: send result of optional diagnostic (injection) |
N |
2058 |
80A |
CMD_B2B_PSHIFTEXT |
B2B internal: request phase shift at low-level rf (extraction) |
N |
2059 |
80B |
CMD_B2B_PSHIFTINJ |
B2B internal: request phase shift at low-level rf (injection) |
N |
2079 |
81F |
CMD_B2B_START |
Start B2B procedure |
Y |
2080 |
820 |
CMD_B2B_MEAS1EXT |
B2B internal: send result of optional measurements (extraction) |
N |
2081 |
821 |
CMD_B2B_MEAS1INJ |
B2B internal: send result of optional measurements (injection) |
N |
4000 |
FA0 |
CMD_GMT_INTERNAL1 |
internal use by the GMT |
N |
4032 |
FC0 |
CMD_UNI_F50DM |
Start of UNILAC 50Hz cycle (sent by Data Master) |
N |
4033 |
FC1 |
CMD_UNI_F50TUNE |
Tune Data Master 50 Hz cycle length (sent by WR-F50 SCU, 1000us after 50 Hz mains trigger signal) |
N |