November 2023: Testing Magnet Probe Signals at SIS18 Extraction

Table of Contents

TL;DR

Test on 3 November 2023. Seems to work.

Introduction

The b2b system uses timestamping with a White Rabbit timing receiver connected to the capacitive / differential signal of the kicker magnet to measure the time of the rising edge and possibly the length of the kicker flat-top. The main purpose is to provide this information to users in hard realtime: The data is sent via timing messages via the White Rabbit network and delivered (!) within less than 1 millisecond after the kick.

comparator-hardware.png
Figure: Comparator hardware.

All software has been merged into the current 'fallout' branch, click.

Measurements

Testing the kicker was done at the following settings
  • pattern SIS18_FAST_HHD_MD_BG
  • dry beam of element nitrogen 7+ gold @ 500 MeV / u
  • at extraction: 1050 kHz revolution frequency, T_rev is 952 ns
  • kicker deflection 4.85 mrad
  • ParamModi value 'kick offset' 2.0 us

The b2b system uses a dedicated system to tap the magnet probe signal at SIS18 (see here). The main new feature in 2023 is a modification to the comparator module that allows to set the comparator level remotely. The main focus of the measurement reported here is to find a good setting of the comparator level. The comparator is connected to the capacitive (differential) signal of kicker module 1.

Comparator

The procedure has been the following.
  1. set comparator level
  2. measure delay of probe signal at comparator output relative to CMD_B2B_TRIGGEREXT
  3. repeat this for different values of the comparator level

A measurement of the comparator response was done. The total measurement time was about half an hour.

comparator level [%] delay rising edge [ns] length output signal
47 n/a n/a
48 n/a n/a
49 n/a n/a
50 3346 3001
51 3352 2982
52 3359 2973
53 3361 1097
54 3366 962
55 3373 562
56 3372 507
57 3378 330
58 3382 233
59 3396 163
60 3405 90
61 n/a n/a
62 n/a n/a
62 n/a n/a
Table: Measured delay of rising edge and length of output signal as a function of comparator level.

Alignment with Digitizer Data

For better comparison with the digitizer data, the delay of the rising edge value of the digitizer signal (at 50%) relative to CMD_B2B_TRIGGEREXT has been determined a couple of times. The average value is a delay of 3307 ns. The calibration of a timestamp measurement with a White Rabbit timing receiver is not known to the nanosecond. However, this internal delay is estimated to about 29 ns.

Data

The data acquired using the comparator and the probe signal acquired by the digitizer connected to module 1 (GS04MK1E: Current_Module1:Triggered@312.5 MHz) are plotted.

2023-11-02_sis18-fast-hhd-module1.png
2023-11-02_sis18-fast-hhd-module1-zoom.png
Figure: Signal of digitizer (blue) and data of the comparator level (red). Top: Complete signal. Bottom: Zoom at rising edge. The x-axis shows the delay after the trigger signal CMD_B2B_TRIGGEREXT. Left y-axis scale: Signal of digitizer [A]. Right y-axis scale: Comparator level [%]. The signal of comparator at a fixed level is shown in green. See text for details.

The above figures show three sets of data.
  • Shown in blue is the signal acquired by the digitizer (left y-axis).
  • The red curve shows delays for rising and falling edge of the output signal delivered by the comparator for different levels (right y-axis); as can be seen, good comparator levels for matching the probe signal are within a range of 50..52%.
  • The green curve (y-axis: arbitrary units) serves to compare the output signal of the comparator at a level of 51% to the digitizer values.

Both figures show the same data, but the lower figure is zoomed onto the rising edge. The rising edge of the digitizer has a risetime (10% -> 90%) of about 125 ns. The comparator is connected to the capacitive differential signal, which is known to be more precise. In principle, the signal by the comparator is expected to be earlier than shown in the figure above. An exact comparison is difficult; as an example, there are distinct cables from the kicker magnet to the cable room for 'probe signal' (digitizer) and the 'differential signal' (comparator); the exact lengths of both sets of cables is not exactly known.

Conclusion

Today (November 2023) the rise time of the kicker magnet probe signal is measured and delivered to users in the entire facility. In 2023 a new comparator has been installed that allows to detect not only the rising but also the falling edge of the kicker signal. What remains to be done is the delivery of the falling edge timestamp.

-- DietrichBeck - 02 Nov 2023
I Attachment Action Size Date Who Comment
2023-11-02_sis18-fast-hhd-module1-zoom.pngpng 2023-11-02_sis18-fast-hhd-module1-zoom.png manage 34 K 02 Nov 2023 - 17:36 DietrichBeck compararator vs digitizer, zoom to rising edge
2023-11-02_sis18-fast-hhd-module1.pngpng 2023-11-02_sis18-fast-hhd-module1.png manage 32 K 02 Nov 2023 - 17:36 DietrichBeck compararator vs digitizer, full signal
comparator-hardware.pngpng comparator-hardware.png manage 794 K 03 Nov 2023 - 10:39 DietrichBeck comparator hardware
Topic revision: r5 - 06 Nov 2023, DietrichBeck
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback