If there is some error, first uninstall the old silecs-eclipse-plugin !
Right click on a silecs-project, select SILECS --> Update SILECS version. This will launch the migration-sript ( a backup of the old doc will be done).
Optionally, for pretty xml formatting: click somewhere into the new xml-code + press STRG(Control)+Shift+F
Validate the new xml (if there are errors, please let me know!)
Re-Generate the code in Silecs
Validate related FESA-files and as well re-generate the code in FESA
Check that the new Makefile.specific are fine ( the old Makefile.specific got renamed to Makefile.specific.backup since the silecs-version to link changed )
Clean & Make first the FESA-class, than the FESA-DU
Release the new FESA binary, make sure that the new .silecsparam files are used !
Needed because the calculation of the checksum changed
Alternatively you can fix the checksum on the PLC by hand
Upload the new PLC-controller-code to the PLC ( Needed because the calculation of the checksum changed )
Take a try ! If there are problems, please let me know!
Dont forget to check the changelog to see how you can profit from the fixes!