White Rabbit Cabling on the GSI/FAIR Campus

Cable Specifications

  • Fiber Optic ITU-T G.652 c or d
  • Wavelength transmission/reception 1490nm/1310nm
  • Connector type:
    • SFPs: LC
    • Splice Boxes: SC
Ref: IEEE802.3-2008 section 5, chapter 59 1000BASE-BX10

Irradiation of Fibres

  • Irradiation at SIS18
  • Irradiation at HHD Cave
  • Setup Test Bed
    • belpc078, slot1: 080030621d97, dev/wbm0, /dev/ttyUSB0
    • belpc078, slot2: 080030621d8d, dev/wbm2(!), /dev/ttyUSB1(!)
    • belpc078, slot3: 08003061a812, dev/wbm1(!), /dev/ttyUSB2(!)
    • belabpc56, slot1: 080030621da1, dev/wbm0, /dev/ttyUSB0
    • belabpc56, slot3: 080030621d86, dev/wbm2(!), /dev/ttyUSB2(!)

Cables, Connections and White Rabbit Switches (deprecated)

  • Information for the equipment under the responsibility of CSCOTG can be found here.
  • Cables connecting equipment not under the responsibility of CSCOTG are labeled using a process that is presently developed by FAIR@GSI.

Splices and Connections (deprecated)

Cable Routes (deprecated)

The timing master is located in the "Betriebsgebäude" (BG 2.009). In a star-like topology, several locations are connected. The names of the splice boxes are identical at both ends.

Timing Master
Room Rack Box Cable fibres Rack Room
BG 2.009 56 BG2A 54K / SB2C 02D (port 1-16) BG2A / SB2C / LW00214 16 Nik SB2.253
BG 2.009 56 BG2A 54K / VR1D 01B (port 17-24) BG2A / VR1D / LWO00215 8 1 VR1.001 (LSB6)
BG 2.009 56 BG2A 54L / NB2Y A3B BG2A / NB2Y / LW00216 16 4 BR3 2.117
BG 2.009 56 BG2A 56J / NE1Z 01A BG2A / NE1Z / LW00217 16 NE1Z BG1.110b
BG 2.009 56 BG2A 56M / BG2A20Z noch eintragen 24 20 BG 2.009
BG 2.009 54 LC patch cables connected at CM switch 2 53 BG 2.009

BG2 (distribution existing facility)
Room Rack Box Cable fibres Rack Room
BG 2.009 21 BG2A 21Z / TH2C 02B noch eintragen 16 2 TH

BG1
Room Rack Box Cable fibres Rack Room
BG1.10b NE1Z SC HHD-Cave->BG1.10b(Rack NE1Z) / (nicht strahlenhart ) 4 N/A HHD
BG1.10b NE1Z SC SIS (SO6MU3E)->BG1.10b (Rack NE1Z) / Nr. 1 (nicht strahlenhart) 4 "Septum" SIS18 SO6
BG1.10b NE1Z SC SIS (SO6MU3E)->BG1.10b (Rack NE1Z) / Nr. 2 (nicht strahlenhart) 4 "Leiter" SIS18 SO6
BG1.10b NE1Z SC SIS/BG1.010B -- SO6MU3E / RACK NE1Z) --> SIS18 / S06 (rad hard) 4 "Leiter" SIS18 SO6

LSB6
Room Rack Box Cable fibres Rack Room
VR1.001 1 NB1C 13I / VR1D 01C NB1C/VR1D / LW00130 16 13 SE1.124
VR1.001 1 VR1D 01D / NB1X 01B VR1D/NB1X / LW00129 16 ?? NB1X

Connected via Patch Cables
SE1.124 - SE1.124A
BR3 2.117 - BR3.2.116

-- DietrichBeck - 15 Apr 2015
Topic revision: r27 - 15 Apr 2015, DietrichBeck
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback