Read MEDDATAI: Read therapy actual values for specified EFI combination. More...
#include <mxs-usrs.hh>
Public Member Functions | |
ReadMEDDATAI (MXSDevice *dev, const string &propname="MEDDATAI") | |
virtual AccDevRetStatus | read (SLong vrtAcc, const AccData &rcvPara, AccData &sndData, AccStamp &stamp, AccEFICD &eficd) |
Read MEDDATAI: Read therapy actual values for specified EFI combination.
If the device controls a separate Hall probe, the field and voltage actual values are always read from there.
Category: slave
Parameters: 3
Start | Name | Type | Description |
0 | method | SLong | Access method for therapy actual values |
1 | select | SLong | To select a specific therapy session |
2 | element | SLong | To select a specific actual value data element |
Data: 3
Start | Name | Type | Description |
0 | volti | SLong | Voltage actual value. |
1 | currenti | Float32 | Current actual value. |
2 | fieldi | Float32 | Field actual value. |
Medlock: none
Access right: free