ReadMAGNINFO Class Reference
[MXS USRs]

Read MAGNINFO: Read collected magnet informations. More...

#include <mxs-usrs.hh>

List of all members.

Public Member Functions

 ReadMAGNINFO (MXSDevice *dev, const string &propname="MAGNINFO")
virtual AccDevRetStatus read (SLong vrtAcc, const AccData &rcvPara, AccData &sndData, AccStamp &stamp, AccEFICD &eficd)

Detailed Description

Read MAGNINFO: Read collected magnet informations.

If the device controls a separate Hall probe, the field and voltage actual values are always read from there.

See also the corresponding single property descriptions for units and valid values.

Category: slave

Parameters: none

Data: 20

Start

Name

Type

Description

0

masterStatus

ULong

Device status

1

dStatus

ULong

Dynamic status

2

activeState

ULong

Active state for this vrtacc

3

inverter

SLong

Inverter position

4

actValMode

SLong

Actual value mode

5

reserved5

SLong

Reserved

6

reserved6

SLong

Reserved

7

reserved7

SLong

Reserved

8

volts

SLong

Voltage set value

9

volti

SLong

Voltage actual value

10

currents

Float32

Current set value

11

currenti

Float32

Current actual value

12

fields

Float32

Field set value

13

fieldi

Float32

Field actual value

14

reserved14

Float32

Reserved

15

reserved15

Float32

Reserved

16

reserved16

Float32

Reserved

17

reserved17

Float32

Reserved

18

reserved18

Float32

Reserved

19

reserved19

Float32

Reserved

Medlock: none