CallDefINIT< T > | Call INIT: Initialize the device |
CallDefMEDMEMBER | Call MEDMEMB: Register device as a therapy member |
CallDefRESET< T > | Call RESET: Reset the device |
CallDefSAVEMST | Call SAVEMST: Save dualport-RAM master data as master data set in local therapy RAM |
CallDefSTORESET | Call STORESET: Store device's therapy data in local flash |
DataType | MAGNINFO data structure |
DataType | CALC data structure |
DevConstDesc | Super device constants |
DevConstType | Structure of super device constants |
MXSDevice | Device class for equipment model pulsed magnets |
ParaType | CALC parameter structure |
ReadACTIV | Read ACTIV: Activates or deactivates a device for the specified virtual accelerator |
ReadCALC | Read CALC: Calculate field, current, and voltage value without affecting the device |
ReadCONNECT | Read CONNECT: Connect magnet with or cut magnet from power supply |
ReadCONSTANT | Read CONSTANT: Read device constants |
ReadCURRENTI | Read CURRENTI: Current actual value in A |
ReadCURRENTS | Read CURRENTS: Current set value in A |
ReadDefACTIVE | Read ACTIV: Read device active state for given virtual accelerator |
ReadDefALRMSTAT< T > | Read ALRMSTAT: Read alarm statistics since Devman (re)start |
ReadDefCHECKSET | Read CHECKSET: Check therapy data sets |
ReadDefCONNDESC< T > | Read CONNDESC: Read description of actual connections of the device |
ReadDefDATAID | Read DATAID: Read master or slave data ID of a data set in local memory or from dualport-RAM |
ReadDefDEVDESC | Read DEVDESC: Read device description |
ReadDefDEVDESC2 | Read DEVDESC2: Read device description compatible with old system |
ReadDefEQMERROR | Read EQMERROR: Read error buffers of device for specified virtual accelerator |
ReadDefINFOSTAT | Read INFOSTAT: Read miscellaneous device state informations |
ReadDefMAXEFI | Read MAXEFI: Read possible and actual Emax, Fmax, and Imax values |
ReadDefMEDIINFO | Read MEDIINFO: Read therapy informations |
ReadDefMEDIMODE | Read MEDIMODE: Read therapy mode |
ReadDefMEDMEMBER | Read MEDMEMB: Read if device is registered as therapy member |
ReadDefNOMEN< T > | Read NOMEN: Read nomenclature of device |
ReadDefOPERMODE | Read OPERMODE: Read operating mode |
ReadDefPOWER | Read POWER: Read if device's power supply is switch on or off |
ReadDefPROPDESC< T > | Read PROPDESC: Read property description of device's equipment model |
ReadDefREQDESC< T > | Read REQDESC: Read description of pending requests of the device |
ReadDefSECURITY | Read SECURITY: Read if device is locked or unlocked |
ReadDefSHUTUP< T > | Read SHUTUP: Read if device sends or does not send alarms |
ReadDefSTATUS< T > | Read STATUS: Read device status |
ReadDefVERSION< T > | Read VERSION: Read EQM, USR, and MIL version strings as well as the EQM variant string |
ReadDSTATUS | Read DSTATUS: Read dynamic (vrtacc-specific) status |
ReadFIELDI | Read FIELDI: Field actual value in Tm |
ReadFIELDS | Read FIELDS: Field set value in Tm |
ReadINFOSTAT | Read INFOSTAT: Read miscellaneous device status informations |
ReadINVERTER | Read INVERTER: Inverter switch of power supply |
ReadMAGNINFO | Read MAGNINFO: Read collected magnet informations |
ReadMAGNSVCI | Read MAGNSVCI: DC voltage actual value in mV |
ReadMAGNSVCS | Read MAGNSVCS: DC voltage set value in mV |
ReadMEDDATAI | Read MEDDATAI: Read therapy actual values for specified EFI combination |
ReadMEDDATAS | Read MEDDATAS: Therapy set values |
ReadMSTDATAS | Read MSTDATAS: Read therapy master data |
ReadMXSCONST | Read MXSCONST: Read MXS specific constants |
ReadPOWER | Read POWER: Mains power switch of power supply |
ReadVOLTI | Read VOLTI: Voltage actual value in mV |
ReadVOLTS | Read VOLTS: Voltage set value in mV |
WriteACTIV | Write ACTIV: Activates or deactivates a device for the specified virtual accelerator |
WriteCONNECT | Write CONNECT: Connect magnet with or cut magnet from power supply |
WriteCOPYSET | Write COPYSET: Copy all slave set values from source to destination virtual accelerator |
WriteCURRENTS | Write CURRENTS: Current set value in A |
WriteDefACTIVE | Write ACTIV: Set device active or inactive for given virtual accelerator |
WriteDefDATAID | Write DATAID: Set data ID |
WriteDefMAXEFI | Write MAXEFI: Set actual Emax, Fmax, and Imax values |
WriteDefOPERMODE | Write OPERMODE: Set operating mode |
WriteDefPOWER | Write POWER: Switch device's power supply on or off |
WriteDefSAVESET | Write SAVESET: Save dualport-RAM slave data as a slave data set in local therapy RAM |
WriteDefSECURITY | Write SECURITY: Lock or unlock device |
WriteDefSHUTUP< T > | Write SHUTUP: Enable or disable the sending of alarms |
WriteFIELDS | Write FIELDS: Field set value in Tm |
WriteINVERTER | Write INVERTER: Inverter switch of power supply |
WriteMAGNSVCS | Write MAGNSVCS: DC voltage set value in mV |
WriteMEDDATAS | Write MEDDATAS: Therapy set values |
WritePOWER | Write POWER: Mains power switch of power supply |
WriteVOLTS | Write VOLTS: Voltage set value in mV |