Class List

Here are the classes, structs, unions and interfaces with brief descriptions:
CallDefINIT< T >Call INIT: Initialize the device
CallDefMEDMEMBERCall MEDMEMB: Register device as a therapy member
CallDefRESET< T >Call RESET: Reset the device
CallDefSAVEMSTCall SAVEMST: Save dualport-RAM master data as master data set in local therapy RAM
CallDefSTORESETCall STORESET: Store device's therapy data in local flash
DataTypeMAGNINFO data structure
DataTypeCALC data structure
DevConstDescSuper device constants
DevConstTypeStructure of super device constants
MXSDeviceDevice class for equipment model pulsed magnets
ParaTypeCALC parameter structure
ReadACTIVRead ACTIV: Activates or deactivates a device for the specified virtual accelerator
ReadCALCRead CALC: Calculate field, current, and voltage value without affecting the device
ReadCONNECTRead CONNECT: Connect magnet with or cut magnet from power supply
ReadCONSTANTRead CONSTANT: Read device constants
ReadCURRENTIRead CURRENTI: Current actual value in A
ReadCURRENTSRead CURRENTS: Current set value in A
ReadDefACTIVERead ACTIV: Read device active state for given virtual accelerator
ReadDefALRMSTAT< T >Read ALRMSTAT: Read alarm statistics since Devman (re)start
ReadDefCHECKSETRead CHECKSET: Check therapy data sets
ReadDefCONNDESC< T >Read CONNDESC: Read description of actual connections of the device
ReadDefDATAIDRead DATAID: Read master or slave data ID of a data set in local memory or from dualport-RAM
ReadDefDEVDESCRead DEVDESC: Read device description
ReadDefDEVDESC2Read DEVDESC2: Read device description compatible with old system
ReadDefEQMERRORRead EQMERROR: Read error buffers of device for specified virtual accelerator
ReadDefINFOSTATRead INFOSTAT: Read miscellaneous device state informations
ReadDefMAXEFIRead MAXEFI: Read possible and actual Emax, Fmax, and Imax values
ReadDefMEDIINFORead MEDIINFO: Read therapy informations
ReadDefMEDIMODERead MEDIMODE: Read therapy mode
ReadDefMEDMEMBERRead MEDMEMB: Read if device is registered as therapy member
ReadDefNOMEN< T >Read NOMEN: Read nomenclature of device
ReadDefOPERMODERead OPERMODE: Read operating mode
ReadDefPOWERRead POWER: Read if device's power supply is switch on or off
ReadDefPROPDESC< T >Read PROPDESC: Read property description of device's equipment model
ReadDefREQDESC< T >Read REQDESC: Read description of pending requests of the device
ReadDefSECURITYRead SECURITY: Read if device is locked or unlocked
ReadDefSHUTUP< T >Read SHUTUP: Read if device sends or does not send alarms
ReadDefSTATUS< T >Read STATUS: Read device status
ReadDefVERSION< T >Read VERSION: Read EQM, USR, and MIL version strings as well as the EQM variant string
ReadDSTATUSRead DSTATUS: Read dynamic (vrtacc-specific) status
ReadFIELDIRead FIELDI: Field actual value in Tm
ReadFIELDSRead FIELDS: Field set value in Tm
ReadINFOSTATRead INFOSTAT: Read miscellaneous device status informations
ReadINVERTERRead INVERTER: Inverter switch of power supply
ReadMAGNINFORead MAGNINFO: Read collected magnet informations
ReadMAGNSVCIRead MAGNSVCI: DC voltage actual value in mV
ReadMAGNSVCSRead MAGNSVCS: DC voltage set value in mV
ReadMEDDATAIRead MEDDATAI: Read therapy actual values for specified EFI combination
ReadMEDDATASRead MEDDATAS: Therapy set values
ReadMSTDATASRead MSTDATAS: Read therapy master data
ReadMXSCONSTRead MXSCONST: Read MXS specific constants
ReadPOWERRead POWER: Mains power switch of power supply
ReadVOLTIRead VOLTI: Voltage actual value in mV
ReadVOLTSRead VOLTS: Voltage set value in mV
WriteACTIVWrite ACTIV: Activates or deactivates a device for the specified virtual accelerator
WriteCONNECTWrite CONNECT: Connect magnet with or cut magnet from power supply
WriteCOPYSETWrite COPYSET: Copy all slave set values from source to destination virtual accelerator
WriteCURRENTSWrite CURRENTS: Current set value in A
WriteDefACTIVEWrite ACTIV: Set device active or inactive for given virtual accelerator
WriteDefDATAIDWrite DATAID: Set data ID
WriteDefMAXEFIWrite MAXEFI: Set actual Emax, Fmax, and Imax values
WriteDefOPERMODEWrite OPERMODE: Set operating mode
WriteDefPOWERWrite POWER: Switch device's power supply on or off
WriteDefSAVESETWrite SAVESET: Save dualport-RAM slave data as a slave data set in local therapy RAM
WriteDefSECURITYWrite SECURITY: Lock or unlock device
WriteDefSHUTUP< T >Write SHUTUP: Enable or disable the sending of alarms
WriteFIELDSWrite FIELDS: Field set value in Tm
WriteINVERTERWrite INVERTER: Inverter switch of power supply
WriteMAGNSVCSWrite MAGNSVCS: DC voltage set value in mV
WriteMEDDATASWrite MEDDATAS: Therapy set values
WritePOWERWrite POWER: Mains power switch of power supply
WriteVOLTSWrite VOLTS: Voltage set value in mV

Generated on 15 Aug 2018 for MXS-USRs by  doxygen 1.6.1