Read MMIINFO: values of MMI More...
#include <dti-usrs.hh>
Public Member Functions | |
ReadMMIINFO (DTIDevice *dev, const string &propname="MMIINFO") | |
virtual AccDevRetStatus | read (SLong vrtAcc, const AccData &rcvPara, AccData &sndData, AccStamp &stamp, AccEFICD &eficd) |
Read MMIINFO: values of MMI
read current values of last multi-multi-injection, works only for devices in SIS-timing
Category: slave
Parameters: none
Data: 137
Start | Name | Type | Description |
0 | count | Float32 | number of multi-multi-injections |
1 | range | Float32 | upper range value in Ampere |
2 | resolution | Float32 | range resolution (0.01 == 1%) |
3 | integrat | Float32 | integration time in seconds |
4 | gainrngs | Float32 | gain range number reference (1..5) |
5 | gainrngi | Float32 | gain range number actual (1..5) |
6 | gainmods | Float32 | gainmode reference (manual, semi/autom. automatic |
7 | gainmodi | Float32 | gainmode reference (manual, semi/autom. automatic |
8 | active | Float32 | active status |
9 | data | MMIDataTypeType[64] |
Medlock: none