#include <dsme-usrs.hh>
Public Member Functions | |
WritePOSITS (DSMEDevice *dev, const string &propname="POSITS") | |
virtual AccDevRetStatus | write (SLong vrtAcc, const AccData &rcvPara, const AccData &rcvData) |
The property read Posits read the set value (nominal position) of anode.
The property write Posits move complete system of Kathode and Anode to new given absolute position of Anode.
Category: master
Parameters: none
Data: 1
Start | Name | Type | Description |
0 | posAnod | SWord | New absolute position of Anode in 1/10mm |
Medlock: all
Access right: device